Flashing is the thin metal or membrane material that directs water over and around the places where a roof is interrupted: a vent pipe, chimney, skylight, wall, valley or edge. Water reaches the roof deck at these points more easily than on open field areas, which is why they are among the first places a roofer checks when a ceiling stains. Good flashing overlaps in layers so water always runs down and out, never behind the layer below.
Why flashing matters more than the roof covering
Shingles, tile and metal panels shed water on open slopes. Where the roof meets something else, the covering stops and the flashing takes over. A U.S. Department of Energy resource on penetrations describes these spots as a weak point in the roof and says the goal is to keep a continuous water-control layer across the whole assembly.
That layer depends on overlap. The same resource says materials should be lapped like shingles so water drains down and out and does not collect, and that metal flashing should be corrosion resistant, fastened with compatible fasteners.
The common flashing types
GAF's consumer guide (May 2026) describes the standard parts.
- Step flashing. Small L-shaped pieces, one per shingle course, overlapped up the slope where a roof meets a wall or chimney.
- Counterflashing. A second piece that sits over the first and is usually set into a masonry joint or the wall. Paired with base flashing, it lets the two parts move independently.
- Valley flashing. Metal in the channel where two slopes meet. It may be open (metal visible) or closed (covered by shingles).
- Drip edge and kickout. Drip edge guides water off the eaves and rakes. A kickout is the bent piece at the bottom of a roof-to-wall joint that sends water into the gutter and away from the wall.
- Pipe flashing. Often a rubber or metal boot or collar around a vent pipe.
Tile and metal roofs use different details, and the installation manual for the specific system governs them.
Where leaks start
Plumbing and exhaust vents
The collar around a pipe is a small detail with several parts: the opening, the base flange, the seal around the pipe and the roof covering over it. The DOE resource shows a sequence in which self-adhered membrane is applied under and over the pipe, a collar is formed around it, and the shingles are cut and lapped to cover the top of the metal collar. The sequence matters because water should meet the overlaps, not the seams.
One rule affects the repair. Miami-Dade's 2018 roofing permit guideline says roofing contractors may not replace or repair rooftop gas-vent flue pipes. Only the appropriate plumbing, mechanical or gas contractor can, under a separate permit. A roofer may only seal the vent's roof flange. Check the current rule with the county, since that document is dated 2018.
Chimneys
Chimneys combine several details: base flashing, step flashing on the sides and counterflashing set into the masonry. The DOE resource flags missing or poorly integrated step flashing and shows counterflashing embedded in the mortar joint. Cracked mortar around the counterflashing is something to point out to a roofer or mason.
Skylights
The DOE resource says skylight curbs need integrated water-management details. A skylight may leak at the frame, the flashing or the glazing seal. Telling these apart takes a close look, ideally by a roofer who also works with skylight units.
Roof-to-wall joints and valleys
The same resource lists roof-to-wall joints and valleys beside penetrations as typical trouble spots. It shows missing step flashing where a gable meets the roof and valley flashing placed on top of shingles when it should lie beneath them.
Edges
FEMA's handbook points out that eaves and edge details are also sensitive to wind. It recommends a drip edge at eaves above the underlayment.
Solar and equipment mounts
Anything bolted through the roof is a penetration. A 2019 FRSA article on solar mounts says Florida code requires flashing that keeps moisture out at penetrations, and that for tile roofs the FRSA/TRI manual then in force called for three-course deck-level flashing on all four sides. See solar panels on a Florida roof for more.
How Florida and Miami-Dade check it
In Miami-Dade, roofing permits carry inspections. The county's inspector checklist shows flashing and penetrations among the items checked on shingle, metal, tile and built-up roofs, along with underlayment, fasteners and, for tile, the uplift test. Inspections happen at stages such as before the underlayment is covered and at final, which is why work should be done under a permit. See roof permit requirements in Miami-Dade.
Two code points to confirm with your building department:
- The FRSA says the Ninth Edition (2026) Florida Building Code, expected to take effect December 31, 2026, ties tile flashing at penetrations to the manufacturer's instructions or the FRSA/TRI Seventh Edition manual. That article notes details may still change before final adoption.
- In the HVHZ, Miami-Dade's roof permit form asks for base and counterflashing details and accepts manufacturer details that comply with RAS-111 and Chapter 15 of the HVHZ provisions of the code. General advice, including this article, may not match what your permit requires.
Signs of a flashing problem
From inside:
- Brown stains on a ceiling near a wall, chimney, skylight or vent
- Stains on attic decking or rafters around a pipe or chimney
- Daylight at a penetration
From the ground or a safe vantage:
- Bent, lifted or missing metal at walls and chimneys
- Cracked or hardened sealant at a boot or collar
- Shingles or tile that have slipped near a penetration
GAF advises checking flashing at least once a year and having a professional handle repairs, and suggests using binoculars from the ground instead of climbing. Roof work carries a real fall risk.
What a proper repair looks like
The DOE resource recommends inspecting first and repairing underlying rot or damage before re-flashing, then flashing every penetration, and following the roof manufacturer's instructions. A coat of sealant over a failing joint may hold for a while but does not rebuild the overlap. If the flashing is old and the roof is near the end of its life, it is usually replaced with the roof. See what causes roof leaks and what to do first.
Questions people ask
Can I just seal around a vent with caulk?
Sealant can stop a small gap temporarily, but flashing works by overlap, not by sealant alone. If the base or collar is cracked, rusted or lifted, the part usually needs replacing. Ask the roofer to explain which it is.
Does a roof repair need a permit?
It depends on the scope. Miami-Dade and each city have their own rules for repairs and re-roofing. Ask the building department before work starts.
Who flashes a new skylight or solar mount?
Both roofers and, in some cases, solar contractors work on penetrations. Responsibility should be written into the contract, including who warrants the roof opening.
Is a leak always at the penetration?
No. Water can travel along the deck or underlayment and appear far from the entry point. A roofer may use water testing or attic inspection to trace it.
Check before you decide
- Ask the roofer to name each penetration and show the flashing detail planned.
- Confirm the flashing materials are corrosion resistant and compatible with the roof covering.
- Ask whether flashing is replaced or reused during re-roofing.
- Make sure any gas vent work is done by the right licensed trade.
- Confirm the permit, product approval and inspection plan with a licensed roofing contractor.
- Keep photos of flashing details before they are covered.
This article is general information. Codes, product approvals and permit rules change, so verify them with the building department.