Skip to main content

WaterSense fixtures: what the label means in South Florida

What the EPA WaterSense label certifies for toilets, showerheads, and faucets, how Miami-Dade's own fixture rules compare, and why it matters here.

By AV Construction Group Corp. Published 6 min read

Illustration for articles about plumbing

WaterSense is a voluntary EPA label for products that use at least 20 percent less water than regular models while performing as well. For fixtures, that means toilets at 1.28 gallons per flush or less, bathroom sink faucets at 1.5 gallons per minute or less, and showerheads at 2.0 gallons per minute or less. In Miami-Dade, the county also has its own water-use efficiency standards for certain new construction and large remodels, so the label is a useful baseline but not the whole picture.

What the label means

EPA sponsors WaterSense in partnership with manufacturers, retailers, builders, and utilities. According to EPA, a labeled product is certified to use at least 20 percent less water than comparable regular models, save energy, and perform as well as or better. The label applies to more than fixtures. It also covers irrigation controllers, new homes, and other products.

The label is not a rating of how well one product compares to another WaterSense model. It tells you the product met EPA's criteria. EPA's WaterSense Products Search lets you look up labeled models.

Toilets

EPA says toilets account for nearly 30 percent of an average home's indoor water use, and older toilets can use as much as 6 gallons per flush. WaterSense labeled toilets use 1.28 gallons per flush or less, which EPA says is about 20 percent less than the 1.6-gallon federal standard.

EPA also says the label requires performance testing. The tests cover flushing mixed testing media, cleaning the bowl, moving waste through the drain line, and waste extraction, as part of the ASME A112.19.2/CSA B45.1 standard.

A caution on versions: EPA's current toilet page says specification version 1.2 is in effect and that a version 2.0 from May 2024 keeps the 1.28-gallon limit, but EPA has paused its effective date. Check EPA's page for the current status before relying on a date.

EPA estimates replacing an old toilet can cut toilet water use by 20 to 60 percent. It also publishes dollar estimates, but these depend on local rates. For your household, use your own bill. If your toilet runs or leaks, repair may come first; see running or leaking toilet causes and the dye test.

Showerheads

EPA says standard showerheads use 2.5 gallons per minute, and WaterSense labeled models must use no more than 2.0 gallons per minute. Labeled models are also certified for spray force, spray coverage, and pressure compensation, so they should feel adequate across a range of household pressures. EPA says the average family could save about 2,700 gallons per year with a labeled showerhead. Showering accounts for nearly 17 percent of residential indoor water use, according to EPA.

Because a labeled showerhead also reduces hot-water use, it reduces water-heating energy. EPA says savings can exceed 330 kilowatt-hours a year for an average household. Your actual savings depend on your water heater type and habits. See water heater replacement in Florida for the heater side.

Faucets and aerators

EPA says the standard bathroom faucet flow is 2.2 gallons per minute. WaterSense labeled bathroom sink faucets and accessories are limited to 1.5 gallons per minute, and EPA says this can cut flow by 30 percent or more. The criteria also require an adequate flow rate at low water pressure. EPA says the average family could save about 700 gallons a year by replacing old faucets or aerators. An aerator is the small screen at the faucet tip, and EPA describes installing a labeled one as being as simple as screwing it on.

EPA notes that public restrooms can use much lower flows, such as 0.5 gallons per minute, but those are not appropriate for private bathrooms. EPA has also said a draft version 2.0 specification, which would lower the maximum to 1.2 gallons per minute, was paused as of February 2025.

Why it matters in South Florida

The region's drinking water comes largely from groundwater. The South Florida Water Management District's draft plan summary says the surficial aquifer system, which includes the Biscayne Aquifer, supplied about 90 percent of public water supply use in the Lower East Coast planning area in 2021. The summary describes conservation as a priority and a low-cost way to meet future demand, and says net public-supply per capita use fell from 176 gallons per day in 2000 to about 131 in 2021. It also describes limits on coastal withdrawals meant to prevent saltwater from moving inland. This is a draft summary; check SFWMD for the final plan.

Miami-Dade Water and Sewer encourages residents to buy WaterSense products. It offers rebates for high-efficiency toilets, faucets, and showerheads, plus free showerheads for residents, according to its water conservation page. The page does not list amounts, eligibility rules, or deadlines, so check the program details before buying.

Miami-Dade's own fixture rules

The county's Water-Use Efficiency Standards Manual, effective January 2009 and described as updated annually, sets requirements for new residential and commercial development and for remodeling permits exceeding 50 percent of a structure's market value. Residential figures in that manual include:

  • Toilets: high-efficiency, 1.28 gallons per flush on average, WaterSense certified. Flush-reduction conversion devices are not accepted.
  • Showerheads: 1.5 gallons per minute maximum, or WaterSense labeled.
  • Lavatory and kitchen faucets: 1.5 gallons per minute maximum at 60 psi inlet pressure.

Note the manual's 1.5 gallons per minute showerhead limit is lower than the EPA label's 2.0 maximum. The manual was written in 2009, before WaterSense certified showerheads, so confirm today's code with the county before choosing a showerhead for a permitted project. The manual also does not address standalone fixture replacement or sale of a home.

Questions people ask

Does WaterSense mean weak flushing or low pressure?

The label requires performance testing for toilets and pressure compensation for showerheads. Individual experiences differ, so check reviews and the product's performance testing information.

Are WaterSense fixtures required in Miami-Dade?

For new development and large remodels the county's standards require efficient fixtures, and for toilets that includes WaterSense certification. Simple replacements may not trigger the same requirement, but the manual does not address that case. Ask the county or a licensed contractor.

Will lower flow lower my bill?

Possibly. Savings depend on usage, rates, and how much hot water is saved. EPA's household estimates are averages.

Check before you decide

  • Look for the WaterSense label and verify the model in the EPA search.
  • If a permit is involved, check whether county standards apply.
  • Ask a licensed plumber to confirm compatibility with your valves and drain line.
  • Check for rebates and their conditions.
  • Fix leaks first. EPA reports that household leaks waste nearly 1 trillion gallons a year nationwide.

For fixture replacement or remodel planning, see plumbing services.

Sources

  1. US EPA WaterSense: About WaterSense
  2. US EPA WaterSense: Residential Toilets
  3. US EPA WaterSense: Showerheads
  4. US EPA WaterSense: Bathroom Sink Faucets
  5. Miami-Dade County: Water-Use Efficiency Standards Manual
  6. Miami-Dade County: Water Conservation
  7. South Florida Water Management District: Lower East Coast Water Supply Plan, Executive Summary (draft, June 2024)

Planning a project?

Tell AV Construction Group Corp. about your project and we will follow up.

Keep reading

More guides on the blog