Most small Florida businesses end up with one of three commercial cooling setups: packaged rooftop units, split systems, or variable refrigerant flow (VRF) systems. Chillers, which cool water that is piped through a building, are normally for larger buildings. The right choice depends on building size, how many separate zones you need, roof or ground space, and who will maintain the equipment. A licensed mechanical contractor or engineer should size and select the system.
The four common types
Packaged units (including rooftop units)
A packaged unit puts the compressor, condenser, evaporator and blower in one cabinet. A federal building-science guide says they are mostly used in small commercial buildings and are usually mounted on a roof or a wall. Trane describes packaged units as combining heating, cooling and air handling in one outdoor cabinet, on a roof or at ground level, with heat from electric strips or a gas furnace.
Typical fit: single-story retail, restaurants, offices and small warehouses where roof or pad space exists. The ductwork delivers air to the space. In Florida, rooftop units sit in sun, salt air and storms, so see rooftop unit maintenance and replacement planning in Miami.
Split systems
A split system separates the indoor air handler from the outdoor condensing unit, connected by refrigerant lines. Trane notes that split systems suit buildings where rooftop access is limited, and that they range from small units for small commercial spaces to much larger sizes. Common uses include office suites, tenant spaces and buildings with no practical rooftop location. Ductless mini-splits are one variant. See mini-split vs central AC in Florida.
VRF (variable refrigerant flow)
The Department of Energy defines a VRF multi-split as a split system with an outdoor unit connected to multiple indoor units on a single refrigerant circuit, with variable-capacity compressors and independent controls for each indoor unit. Heat pump versions can also heat.
What that means in practice: separate zones can have different temperatures, and capacity changes with demand. LG, a manufacturer that sells both, describes VRF as well suited to buildings with diverse spaces and uses that need zoned control, and as easy to tie into a building management system. That is a manufacturer's view, so ask for a comparison based on your own building.
Chillers
A chiller cools water, which is piped to air handling units around the building. The Department of Energy's 2016 report says smaller light-commercial buildings commonly use air as the distribution medium, while larger buildings more commonly use chilled-water systems. LG describes chillers as generally lower in equipment cost with high efficiency, and suited to large facilities that need constant cooling. For most small businesses, a chiller is more than the building needs. It is typically a consideration for large or multi-tenant buildings.
Matching the system to your building
Questions that drive the choice:
- Size and layout. DOE says commercial air conditioning spans roughly 5 to 2,000 tons, so a small shop and a large complex are different problems.
- Zones. If a break room, server closet and sales floor need different temperatures, a zoned rooftop system, several splits or a VRF is worth discussing.
- Roof and structure. Rooftop units need structural support, access and wind anchoring. Miami-Dade's mechanical inspection checklist includes items such as equipment support, anchorage, rooftop clearances and fall protection near roof edges. Splits and VRF place condensers at grade, on a rack or on the roof.
- Humidity load. Customers coming and going, kitchens and outdoor air requirements add moisture. A federal guide warns that oversizing causes short cycling and poor moisture removal in humid climates. That guide is written for homes, but the principle applies to commercial equipment too. Ask how the design handles ventilation air and humidity.
- Hours of use. A space used evenings only, or a 24-hour operation, changes equipment choice and redundancy.
- Existing infrastructure. Ductwork, electrical capacity and roof curbs can favor a like-for-like replacement or require upgrades.
- Maintenance capacity. Chilled-water and VRF systems need qualified service. Confirm that local contractors support the brand and that you have a maintenance plan.
Efficiency and labels
ENERGY STAR covers commercial unitary air conditioners, heat pumps and VRF multi-split systems, grouped by size: under 65,000 Btu/h, 65,000 to under 135,000 Btu/h, and 135,000 to under 240,000 Btu/h. A certified model must meet all listed criteria for its type and size. The page lists gas/electric packaged units as a covered type without criteria for them, and it states no effective date, so check ENERGY STAR for current details.
Licensing and permits
In Florida, the air-conditioning contractor class matters on larger jobs. State law defines a Class A contractor as having unlimited scope for central air-conditioning systems, and a Class B contractor as limited to systems up to 25 tons of cooling and 500,000 Btu of heating in any one system. A large multi-unit or hydronic project may therefore require a Class A. See AC permit and licensing rules.
Tenant buildouts and equipment changes have their own permit steps. See commercial tenant improvement permits in Miami-Dade. Landlord approval is often needed before you alter roof equipment. Confirm requirements with the local building department, since rules vary by city.
Questions people ask
Which type is cheapest?
No cost figure is given here because costs depend on the building, equipment, labor and market, and no dated source applies to your project. Ask for itemized bids that list equipment, ductwork, electrical, roof work, permits and controls, and compare operating costs, not just installed cost.
Can I mix system types?
Yes. Buildings often use rooftop units for the main space and a split or mini-split for a server closet or 24-hour area. LG's example of a shopping center using chillers and VRF together shows mixing at a larger scale.
Is VRF always more efficient?
Not necessarily. It depends on the design, the building load and the operating hours. Manufacturer claims differ. Ask the designer to compare options using your building's load calculation.
Check before you decide
- Get a load calculation, not a guess based on the old unit size.
- List zones and hours of use.
- Check roof structure, pad space and access.
- Confirm the contractor's Florida license class and that the permit will be pulled.
- Ask about ventilation air and humidity control in the design.
- Compare itemized bids and long-term maintenance needs.